Optimal Drive Technology

How to choose the right radio frequency for telemetry applications

Author : Ian Loudon, Omniflex

13 October 2022

In highly regulated industries where laying cables is not feasible, radio-based communication can transfer critical data from multiple locations wirelessly and effectively. When installing radio equipment and telemetry devices, such as transmitters and receivers, in an industrial facility or field-based utility applications like gas, electricity and water, frequency is an important consideration.

Here, Ian Loudon, International Sales and Marketing Manager at Omniflex, outlines considerations for when selecting a radio frequency (RF) on which to operate.

The UK’s radio spectrum is more cluttered than ever. Space on bands is already at a premium and, with more and more businesses setting up radio equipment, demand will only increase.

For many businesses, the need to pay a fee for exclusive transmission rights means operating on a licensed band is undesirable. Instead, many opt for license-free bands that are open to everyone. As a result, they can transmit essential data while complying with legislation, such as the new Radio Equipment Regulation (RER), which sets the standard for the UK’s radio communications.

Until January 2018, there were just eight frequencies for license-free radios in the UK, ranging from 446.00625MHz to 446.09375MHz. Since then, the frequency spectrum has expanded significantly. For example, the 5GHz band runs from 5,150MHz to 5,850MHz, before being broken down into three A-C bands. Two of the most common unlicensed bands in the UK are 2.4GHz, which is the same frequency as WiFi and Bluetooth, and 868MHz.

Higher frequencies

When selecting higher frequencies such as 2.4GHz, these will often have more “channels” available than lower RFs, meaning devices can be set to avoid channels that are already occupied by other equipment.

The bandwidth is also greater and businesses can transmit more data faster than when operating on a lower frequency. For example, wireless SCADA systems typically use very high frequencies (VHF) and ultra-high frequencies (UHF) over a long range and rely on fast transmissions.

However, the higher the frequency the shorter the range, and the more vulnerable to interference. Ideally, businesses will select these bands for indoor applications where there are shorter distances between radio equipment. Walls, rain and even fog can negatively impact signal integrity, so high RFs are often unsuitable for outdoor settings.

In recent years, the 2.4GHz spectrum has become even more crowded, with more businesses taking advantage of nonexclusive access. Therefore, when installing radio equipment, there is already a considerable number of devices on the same band.

The inclusion of additional items could make the band more vulnerable to interference. Consequently, more people have started using 5GHz for WiFi applications because it can carry more data and is faster than 2.4GHz. Nevertheless, its narrow coverage area and lack of penetrability mean its application is often confined to residential settings.

Lower frequencies

In contrast, 868MHz can transmit across longer distances and penetrate most objects. Although it requires a larger antenna than 2.4GHz, it has a range of up to 800m and lower power consumption.

While mobile phones, WiFi networks and other similar devices operate on 2.4GHz, 868 MHz can support much of the radio equipment found in industrial settings, such as remote sensing, security and alarm systems.

Despite offering nonexclusive access, interferences are rare on 868MHz bands. While open to all devices, 868MHz is only really used for industrial, scientific and medical applications, meaning there’s less competition from neighbouring sites for bandwidth.

However, there is a trade-off. Although lower frequencies have a larger transmission range, they also have a longer delay spread, which can result in a degraded signal due to interference. Therefore, although 868 MHz and other frequencies like IEEE 802.11af can be used in outdoor environments, vegetation and weather remain problematic and multipath is introduced, increasing the delay spread further.

When choosing between higher and lower frequencies, power is an important consideration. The RER prohibits interference by preventing users from amplifying their signal to block out others, and every frequency has a different maximum permitted transmission level.

Regardless of the selected frequency, the gain of the antenna cannot result in equipment exceeding the effective radiated power (ERP) permitted for that band. For instance, the maximum ERP on the 868MHz frequency for short-range and wideband devices is limited to 25dB, with a duty cycle of 10 percent.

Weighing up the options

Higher and lower frequencies have their benefits and drawbacks, but the proof really is in the application. When specifying an RF for any industrial equipment or telemetry devices, it’s important to know the required transmission range, what the surrounding obstacles are and the likelihood of attenuation.

Before purchasing any radio equipment or telemetry devices, such as remote monitoring systems for industrial settings, it is important to work with an experienced, flexible partner that offers technology that can adapt to the different bands.

A sound partner can integrate radio equipment and telemetry systems over different RFs seamlessly, providing support from the initial enquiry to purchasing and installation.

Omniflex offers the Teleterm M3R, a small programmable RTU that is configurable and allows users to choose between analogue and digital inputs and outputs. Facility managers can integrate them with SCADA systems to achieve wireless connectivity in different license-free bands. 

In the UK, most industrial facilities rely on unlicensed bands, and facility managers must choose between higher frequencies like 2.4GHz for shorter-range, indoor communications and 868MHz for longer-distance transmissions.

There are various application-specific considerations when specifying an RF, including the surroundings and likelihood of attenuation. When purchasing any radio equipment, facility managers can make the process easier by working with a partner that offers flexibility in their products.

To discover more about Omniflex’s radio terminal units for wireless telemetry and communication, visit the company’s website for more information.


Contact Details and Archive...

Print this page | E-mail this page


Tesys 100

This website uses cookies primarily for visitor analytics. Certain pages will ask you to fill in contact details to receive additional information. On these pages you have the option of having the site log your details for future visits. Indicating you want the site to remember your details will place a cookie on your device. To view our full cookie policy, please click here. You can also view it at any time by going to our Contact Us page.